Description
PR 4179 Universal AC / DC transmitter – PR Electronics
The PR Electronics 4179 Universal AC/DC Transmitter is a highly accurate device designed to measure AC current and voltage signals and convert them into standard analog outputs. With passive or active current output, voltage output, and functional safety compliance, the PR 4179 delivers reliable signal conditioning for critical process applications.
Key Features
Measures AC current up to 5 AAC RMS and AC voltage up to 300 VAC RMS
Outputs: active unipolar/bipolar mA, passive 2-wire mA, and voltage signals
Response time < 0.75 s and accuracy better than 0.3%
Universal power supply: 21.6…253 VAC / 19.2…300 VDC
Configurable input limits for safety and error handling
3-port galvanic isolation (2.3 kVAC) for safe operation
Fully programmable via PR 4500 detachable display series
Applications
Current transformer measurement (0–5 AAC RMS)
Supply voltage monitoring (0–300 VAC RMS)
Conversion of narrow AC inputs to wide unipolar/bipolar outputs (e.g., 0–1 VAC input to ±10 V or 4–20 mA output)
Safety-critical process monitoring with SIL 2 and ISO-13849 Performance Level d compliance
Signal conditioning in industrial automation, power, and energy systems
Technical Highlights
Accuracy: < 0.3% of span | Signal/noise ratio: > 60 dB
Programmable output ranges: 0–20, 4–20, ±10, ±20 mA and 0/1–5 V, 0/2–10 V, ±1/±10 V
Passive 2-wire loop-powered mA output supported
Adjustable response time: 0.0–60.0 s
Exceptional output stability: < 0.001% span/100 Ω
Compliance with NAMUR NE21 (EMC immunity) and NAMUR NE43 (sensor error detection)
Certifications & Approvals
c UL us, UL 508 (E248256)
RoHS, EMC, LVD, EAC compliant
SIL hardware assessed for functional safety applications
Product Details
Part Number: PR 4179
Product Name: Universal AC/DC Transmitter
Manufacturer: PR Electronics
Origin: Denmark
Condition: New / Original Packing
PR 4179 Universal AC / DC transmitter from PR Electronics with mA/Voltage output.
PR Electronics 4179 | AC to DC Converter | PR 4179 Universal AC DC Transmitter | AC Voltage Current Transmitter | Passive Active Current Output Transmitter | Fast Response Signal Transmitter | SIL 2 Certified AC DC Transmitter | Voltage Monitoring Transmitter | Universal AC Current Signal Converter | Industrial Process Signal Transmitter | 4179 High Accuracy Transmitter | AC Current to mA/V Converter | AC Voltage to DC mA/V Converter | Bipolar AC DC Converter | CT Current Transmitter
Application
- The 0…5 AAC RMS range makes it possible to accurately measure a typical current transformer.
- The 0…300 VAC RMS range allows accurate supply voltage monitoring.
- The 4179 measures standard input ranges, and can be freely configured to customer-defined input range.
- Converts narrow AC current / voltage inputs to wide bipolar or unipolar outputs, e.g. 0…1 VAC RMS input = ±10 volt or 4…20 mA output with a minimum span of 0.5 AAC RMS or 0.5 VAC RMS.
- Configurable input limits control the output value for increased safety.
- The 4179 has been designed according to strict safety requirements and is therefore suitable for application in SIL 2 installations.
- Suitable for the use in systems up to Performance Level “d” according to ISO-13849.
Technical characteristic – 4179 Universal AC / DC transmitter
- The latest analog and digital techniques are used to obtain maximum accuracy and immunity to interference.
- Possibility of output safety feedback by selecting S4…20 mA output.
- The current output can drive up to 800 Ohms, with an adjustable response time of 0.0…60.0 seconds.
- Exceptional mA output load stability of <0.001% of span / 100 Ohm.
- Meets the NAMUR NE21 recommendations, ensuring high accuracy in harsh EMC environments.
- Meets the NAMUR NE43 recommendations, allowing the control system to easily detect an input error.
- Tested to a high 2.3 kVAC, 3-port galvanic isolation level.
- Excellent signal to noise ratio of > 60 dB.
Mounting / installation / programming – 4179 Universal AC / DC transmitter from PR Electronics
- Very low power consumption means units can be mounted side by side without an air gap – even at 60°C ambient temperature.
- Configuration, monitoring, 2-point process calibration and more are accomplished using PR’s 4500 series of detachable displays.
Data sheet
Environmental Conditions
| Operating temperature | -20°C to +60°C |
| Storage temperature | -20°C to +85°C |
| Calibration temperature | 20…28°C |
| Relative humidity | < 95% RH (non-cond.) |
| Protection degree | IP20 |
| Installation in | Pollution degree 2 & meas. / overvoltage cat. II |
Mechanical specifications
| Dimensions (HxWxD) | 109 x 23.5 x 104 mm |
| Dimensions (HxWxD) w/ PR 4500 | 109 x 23.5 x 131 mm |
| Weight approx. | 155 g |
| Weight incl. 4501 / 451x (approx.) | 170 g / 185 g |
| DIN rail type | DIN EN 60715/35 mm |
| Wire size | 0.13…2.08 mm2 AWG 26…14 stranded wire |
| Screw terminal torque | 0.5 Nm |
| Vibration | IEC 60068-2-6 |
| 2…13.2 Hz | ±1 mm |
| 13.2…100 Hz | ±0.7 g |
Common specifications
Supply | |
| Supply voltage, universal | 21.6…253 VAC, 50…60 Hz or 19.2…300 VDC |
| Max. required power | 1.6 W |
| Max. power dissipation – current measurement | 2.7 W |
| Max. power dissipation – voltage measurement | 1.6 W |
Isolation voltage | |
| Test voltage | 2.3 kVAC |
| Working voltage | 250 VAC (reinforced) / 500 VAC (basic) |
Response time | |
| Response time (0…90%, 100…10%) | < 0.75 s |
| Programming | PR 4500 communication interfaces |
| Signal dynamics, input | 20 bit |
| Signal dynamics, output | 18 bit |
| Signal / noise ratio | > 60 dB |
| Output referred common mode rejection ratio | 0.02 ppm / VHz |
| Accuracy | Better than 0.3% of selected range* |
| EMC immunity influence | < ±0.5% of span* |
| Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span* |
| of span | = of selected standard range |
Input specifications – 4179 Universal AC / DC transmitter
Current input | |
| Signal range | 0…5 AAC / 40…400 Hz |
| Maximum input limit | 6.00 AAC @ 40°C |
| Programmable measurement ranges | 0…0.5; 0…1; 0…2.5 & 0…5 AAC |
| Custom configurable signal range | 0…5 AAC /40…400 Hz |
| Min. measurement range (span) | 0.5 AAC |
| Input resistance | < 0.042 Ω (incl. terminals) |
Voltage input | |
| Signal range | 0…300 VAC / 40…400 Hz |
| Programmable measurement ranges | 0…0.5, 0…1, 0…2.83, 0…5, 0…120, 0…230 & 0…300 VAC |
| Custom configurable signal range | 0…300 VAC / 40…400 Hz |
| Min. measurement range (span) | 0.5 VAC |
| Input resistance | Nom. 3 MΩ || 100 pF |
Output specifications – 4179 Universal AC / DC transmitter
Active unipolar and bipolar mA output | |
| Programmable ranges | 0…20, 4…20 and S4…20 mA ±10 and ±20 mA Direct or Inverted Action |
| Load (@ current output) | ≤ 800 Ω |
| V-curve function, active signals, 100-0-100% | 20-0-20 mA |
Passive 2-wire mA output | |
| Programmable ranges | 0…20 and 4…20 mA Direct or Inverted action |
| V-curve function, 100-0-100% | 20-0-20 mA |
| External loop supply | 3.5…30 V |
Current output | |
| Signal range | 0…23 mA (unipolar) -23…+23 mA (bipolar) |
| Current limit | ≤ 28 mA (unipolar) ± 28 mA (bipolar) |
| Load stability | ≤ 0.001% of span / 100 Ω |
| Response time, programmable | 0.0…60.0 s |
Voltage output | |
| Programmable signal ranges | 0/0.2…1; 0/1…5 ; 0/2…10; 1…0.2/0; 5…1/0; 10…2/0 V ±1, ±5 and ±10 V Direct or Inverted action |
| V-curve function, 100-0-100% | 1-0-1, 5-0-5 and 10-0-10 V |
| Load (@ voltage output) | ≥ 500 kΩ |
| Response time, programmable | 0.0…60.0 s |
Observed authority requirements
| EMC | 2014/30/EU & UK SI 2016/1091 |
| LVD | 2014/35/EU & UK SI 2016/1101 |
| RoHS | 2011/65/EU & UK SI 2012/3032 |
| EAC | TR-CU 020/2011 |
Approvals -4179 Universal AC / DC transmitter
| c UL us, UL 508 | E248256 |
| SIL | Hardware assessed for use in SIL applications |