Description
PR 4184 Universal uni-bipolar signal transmitter – PR Electronics
The PR Electronics 4184 is a high-performance universal uni-/bipolar signal transmitter designed for precise measurement and conversion of DC voltage and current signals. With a fast < 20 ms response time, excellent 0.05% accuracy, and flexible unipolar/bipolar input-output configuration, the PR 4184 delivers reliable signal conditioning for demanding industrial applications.
Key Features
Measures DC inputs up to ±300 V / ±100 mA with spans as low as 25 mV / 0.5 mA
Passive/active current output and buffered ±20 V voltage output
Fast < 20 ms response time with programmable delay up to 60 s
Accuracy better than 0.05% of span
Universal supply: 21.6…253 VAC / 19.2…300 VDC
3-port galvanic isolation (2.3 kVAC) for maximum safety
Fully programmable via PR 4500 detachable display series
Applications
Measurement of torque, position, acceleration, and current sensors
Conversion of narrow bipolar signals (e.g. ±1 V) to wide bipolar/unipolar outputs (e.g. ±10 V, 4…20 mA)
Buffered ±20 VDC output for control devices such as PVG 32 valves
Proportional and inverse control applications with selectable I/O action
SIL 2 and ISO-13849 Performance Level “d” compliant for functional safety applications
Reliable performance in marine and harsh EMC environments
Technical Highlights
Input ranges: up to ±300 VDC and ±100 mA
Outputs: current ±23 mA, voltage ±23 V, passive 2-wire mA, buffered/shunted outputs
Load stability: < 0.001% span/100 Ω
Signal dynamics: 24-bit input / 18-bit output
Compliance with NAMUR NE21 and NE43 recommendations
Compact DIN rail mount housing: 109 x 23.5 x 104 mm
Certifications & Approvals
c UL us, UL 508 (E248256)
RoHS, EMC, LVD, EAC compliant
SIL hardware assessed for use in safety applications
Product Details
Part Number: PR 4184
Product Name: Universal Uni-/Bipolar Signal Transmitter
Manufacturer: PR Electronics
Origin: Denmark
Condition: New / Original Packing
PR 4184 Universal uni-bipolar signal transmitter
PR Electronics 4184 | PR 4184 Universal Signal Transmitter | Uni Bipolar Signal Converter | DC Voltage Current Transmitter | Fast Response Signal Transmitter | SIL 2 Certified Transmitter | Buffered Voltage Output Transmitter | Industrial Automation Signal Converter | Marine Approved Signal Transmitter | 4184 High Accuracy Transmitter | Potentiomer Transmitter / Converter | POT Transmitter | 3 Wire Transmitter
Application
- Fast < 20 ms response time for measuring signals produced by torque, position, current & acceleration sensors.
- User configurable bipolar or unipolar I/O means the 4184 is suitable for nearly any DC voltage or current conversion.
- Freely programmable between ±300 VDC and ±100 mA.
- The excitation source allows measurement of a 2-wire or 3-wire transmitter, or a potentiometer.
- Converts narrow bipolar inputs to wide bipolar or unipolar outputs, e.g., ±1 volt input = ±10 volt or 4…20 mA output.
- Configurable input limits control the output value for increased safety.
- ±20 VDC buffered voltage output for controlling devices like the PVG 32 valve (6…18 VDC).
- Designed according to strict safety requirements and is therefore suitable for application in SIL 2 installations.
- Suitable for the use in systems up to Performance Level “d” according to ISO-13849.
Technical characteristics
- The latest analog and digital techniques are used to obtain maximum accuracy and immunity to interference.
- Possibility of output safety readback by selecting S4…20 mA output.
- The current output can drive up to 1000 Ohms, with an adjustable response time of 0.0…60.0 seconds.
- Exceptional mA output load stability of < 0.001% of span / 100 Ohm.
- Meets the NAMUR NE21 recommendations, ensuring high accuracy in harsh EMC environments.
- Meets the NAMUR NE43 recommendations, allowing the control system to easily detect a sensor error.
- Tested to a high 2.3 kVAC, 3-port galvanic isolation level.
Mounting / installation / programming
- Very low power consumption means units can be mounted side by side without an air gap – even at 60°C ambient temperature.
- Configuration, monitoring, 2-point process calibration and more are accomplished using PR’s 4500 series of detachable displays.
Environmental Conditions – PR 4184 Universal uni-bipolar signal transmitter
| Operating temperature | -20°C to +60°C |
| Storage temperature | -20°C to +85°C |
| Calibration temperature | 20…28°C |
| Relative humidity | < 95% RH (non-cond.) |
| Protection degree | IP20 |
Mechanical specifications
| Dimensions (HxWxD) | 109 x 23.5 x 104 mm |
| Dimensions (HxWxD) w/ PR 4500 | 109 x 23.5 x 131 mm |
| Weight approx. | 155 g |
| Weight incl. 4501 / 451x (approx.) | 170 g / 185 g |
| DIN rail type | DIN EN 60715/35 mm |
| Wire size | 0.13…2.08 mm2 AWG 26…14 stranded wire |
| Screw terminal torque | 0.5 Nm |
Common specifications -PR 4184 Universal uni-bipolar signal transmitter
Supply | |
| Supply voltage, universal | 21.6…253 VAC, 50…60 Hz or 19.2…300 VDC |
| Max. required power | ≤ 2.5 W |
| Internal power dissipation | ≤ 2.0 W |
Isolation voltage | |
| Test voltage | 2.3 kVAC |
| Working voltage | 250 VAC (reinforced) / 500 VAC (basic) |
Response time | |
| Response time (0…90%, 100…10%) | < 20 ms |
Auxiliary supplies | |
| 2-wire loop supply | > 16 V @ 23 mA |
| 3-wire loop supply | > 18…< 28 V @ 23…0 mA |
| Loop supply limitation | 27…35 mA avg., < 80 mA peak |
| Reference voltage | 2.5 VDC ±0.5% |
| Reference voltage, load | 0…15 mA |
| Current limit, reference voltage | < 60 mA |
| Programming | PR 4500 communication interfaces |
| Signal dynamics, input | 24 bit |
| Signal dynamics, output | 18 bit |
| Signal / noise ratio | > 60 dB |
| Bandwidth | > 40 Hz |
| Accuracy | Better than 0.05% of selected range |
| EMC immunity influence | < ±0.5% of span |
| Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span |
| Conducted emission, cl. A | 150 kHz…10 MHz |
Input specifications – PR 4184 Universal uni-bipolar signal transmitter
Current input | |
| Signal range | ±100 mA |
| Programmable measurement ranges | 0…1, 0…5, 1…5, 0…20, 4…20, ±1, ±5, ±10, ±20, ±50, ±100 mA |
| Custom configurable signal range | ±100 mA |
| Min. measurement range (span) | 0.5 mA |
| Input voltage drop | 0.6 V @ 20 mA nom. |
Voltage input | |
| Signal range | ±300 VDC |
| Programmable measurement ranges | 0…0.1, 0…1, 0.2…1, 0…2.5, 0…5, 1…5, 0…10, 2…10, 0…100, 0…300, ±0.1, ±1, ±2.5, ±5, ±10, ±100, ±300 V |
| Custom configurable signal range | ±300 V |
| Min. measurement range (span) | 25 mV |
| Input resistance | Nom. 3 MΩ (> 2.5 VDC) Nom. > 10 MΩ (≤ 2.5 VDC) |
Potentiometer input | |
| 3-wire potentiometer input | 0…100% |
| Reference voltage | 2.5 V |
| Calibration resistance | 5 kΩ |
| Min. potentiometer resistance | 200 Ω |
Output specifications – PR4184 Universal uni-bipolar signal transmitter
Current output | |
| Signal range | 0…23 mA (unipolar) -23…+23 mA (bipolar) |
| Custom config. output range | ±20 mA |
| Min. signal range | 4 mA |
| Load (@ current output) | ≤ 1000 Ω / ± 20 V @ ±20 mA |
| Current limit | ≤ 28 mA (unipolar) ± 28 mA (bipolar) |
| Load stability | ≤ 0.001% of span / 100 Ω |
| Response time, programmable | 0.0…60.0 s |
Passive 2-wire mA output | |
| Programmable ranges | 0…20 and 4…20 mA |
| Ext. 2-wire loop supply range | 3.5…28.8 VDC |
Voltage output | |
| Programmable signal ranges | 0/0.2…1; 0/1…5 ; 0/2…10 V ±1, ±5 and ±10 V Direct or Inverted action |
| Load (@ voltage output) | ≥ 500 kΩ |
| Response time, programmable | 0.0…60.0 s |
Shunted voltage output | |
| Signal range | ± 1.2 V / ± 12 V |
| Programmable standard ranges | 0…1, 0…2.5, 0…5, 1…5, 0…10, 2…10 V ±1, ±2.5, ±5, ±10 V |
| Min. span | 0.8 V |
| Custom config. output range | ±10 V |
| Load, min. | > 500 kΩ |
Buffered voltage output | |
| Signal range | ± 23 V |
| Programmable standard ranges | 0…1, 0.2…1, 0…2.5, 0…5, 1…5, 0…10, 2…10, 0…20, 4…20; ±1, ±2.5, ±5, ±10, ±20 V |
| Min. span | 0.8 V |
| Custom config. output range | ±20 V |
| Current limit | < 50 mA |
| Load, min. | > 2 kΩ |
Observed authority requirements
| EMC | 2014/30/EU & UK SI 2016/1091 |
| LVD | 2014/35/EU & UK SI 2016/1101 |
| RoHS | 2011/65/EU & UK SI 2012/3032 |
| EAC | TR-CU 020/2011 |
Approvals – PR 4184 Universal uni-bipolar signal transmitter
| c UL us, UL 508 | E248256 |
| SIL | Hardware assessed for use in SIL applications |